Rise Time: | 1-6 Levels | Humidification: | 1-5 Levels (113 To 185°F/45 To 85°C) |
---|---|---|---|
Ramp Time: | 0 To 45 Min (5-minute Increments) | Mode: | CPAP S, S/T |
Pressure Range (cmH2O): | IPAP:4-30 EPAP:4-25 CPAP:4-20 | Data Storage Capacity: | >1 Year, Micro SD Card 4G |
High Light: | 6 Levels Rise Time Home Care Ventilator,Sepray Series Home Care Ventilator,6 Levels Rise Time home based ventilator |
Micomme COPD solution
Description
Home Non-invasive ventilation (NIV) with bi-level positive airway pressure (BiPAP) is commonly used to treat patients admitted to hospital with acute hypercapnic respiratory failure (AHRF) secondary to an acute exacerbation of chronic obstructive pulmonary disease (AECOPD).
Home Non-invasive ventilation at home improves survival and decreases healthcare utilization in medicare beneficiaries with Chronic Obstructive Pulmonary Disease with chronic respiratory failure which can reduce mortality and the number of repeat respiratory failure and readmissions by continuing the acute noninvasive ventilatory therapy as a long-term therapy.
Application
Chronic Obstructive Pulmonary Disease, it is a type of obstructive lung disease characterized by long-term breathing problems and poor airflow. The main symptoms include shortness of breath and cough with sputum production. COPD is a progressive disease, meaning it typically worsens over time.
Emphysema is a lung condition that causes shortness of breath. In people with emphysema, the air sacs in the lungs (alveoli) are damaged. Over time, the inner walls of the air sacs weaken and rupture — creating larger air spaces instead of many small ones.
Advantage
360° anti-back flow patent water chamber which can prevent the water in the chamber from returning to main machine when the water is below the highest level.
Unique anti dry burning technology, when the temperature is higher than the limiting temperature, the device will automatically stop heating.
Intelligent and safe, it can automatically control the temperature of the heater below 80 ℃.
13 intelligent alarm modules, including 13 abnormal alarms and low tidal volume alarm, ensure the safety of patients.
Specifications
Description | ST-30D |
Mode | CPAP S, S/T |
Pressure range (cmH2O) |
IPAP:4-30 EPAP:4-25 CPAP:4-20 |
Rise time | 1-6 levels |
Backup Rate (BPM) | 5-30 |
COMF pressure relief |
1-3 levels |
Humidification | 1-5 levels (113 to 185°F/45 to 85°C) |
Ramp time | 0 to 45 min (5-minute increments) |
Data storage capacity |
>1 year, Micro SD Card 4G |
Dimensions (L x W x H) |
24.5×16×10.5 cm |
Weight | 1.75 kg |
Mean sound level | ≤28 dB |