Oxygen Ajustment: | Automatic | Oxygen Range: | 21%~100% |
---|---|---|---|
Flow: | 10-70L/min | Temperature: | 31-37℃ |
Trend Review: | 1,3,7 Days | ||
High Light: | 100% Oxygen High Flow Therapy Machine,100% Oxygen High Flow Nasal Cannula System,100% Oxygen hfnc machine |
21%~100% Oxygen High Flow Therapy Machine / High Flow Nasal Cannula System
Description
HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.
HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting.
Application
Acute hypoxic respiratory failure (ARF) was the first condition treated with HFNC in adults. The use of heated and humidified high flow nasal cannula (HFNC) has become increasingly popular in the treatment of patients with acute respiratory failure through all age groups.
HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.
Avantage
The first company to research, develop and produce high-flow in China.
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
Effectively reduce the dead space with 70L/min high flow
Intelligent water-controlling system, automatically refills and maintains the optimal water level in the water chamber.
The machine uses timing function, which is convenient for nurses to charge by time.
The machine uses timing function, which is convenient for nurses to charge by time.
Specifications
Parameters | OH-70C |
Oxygen Adjustment Setting | Automatic |
Oxygen Adjustment Range | 21%- 100% |
Low flow mode | 2- 25L/min |
High flow mode | 10- 70L/min |
Temperature settings | 31℃- 37℃ |
Real time display parameters | Preset Flow, Preset FiO2, Preset Temperature, Treatment time |
Trend review | 1,3,7 days review |
Content of review | Flow, FiO2, Temperature, Treatment time |
Presetting of treatment time | Yes |
Auto reminder of maintenance | Yes |
Main device disinfection | No need disinfection for circuits system Wipe disinfection for device surface |
Screen |
4.3 inches |
Dimension | 340*228*162mm |
Weight | 3.3kg |
Alarm | Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching preset treatment time alarm |