Color: | White And Grey | Mode: | S/T, CPAP, S, T, PC, VAT, HFNC |
---|---|---|---|
Screen Size: | 5.7 Inch Color Screen | Oxygen Concentration: | 21%~100%, (increment By 1%) |
Target Tidal Volume: | 20~2500mL | Backup BPM: | 1~60BPM |
Flow Of HFNC Mode: | 10~70L/min | Max Flow: | 300L/min |
Max Leak Compensation: | 120L/min | IPAP: | 4~40cm H2O |
EPAP: | 4~25cm H2O | CPAP: | 4~20cm H2O |
High Light: | 300L/Min Non Invasive Ventilator Machine,300L/Min non invasive breathing machine,ST-30K Non Invasive Ventilator Machine |
HIGH PERFORMANCE NON-INVASIVE VENTILATOR ST-30K with HFNC SOLUTION for HOSPITAL USE
Description
Noninvasive ventilation (NIV) supports the patient's breathing without the need for intubation or a tracheotomy. NIV delivers effective therapy with less risk of infection and improved survival in patients with respiratory failure.
Noninvasive ventilation supports the patient by delivering the right inspiratory and expiratory pressures or tidal volumes to support their individual ventilatory demand, enhancing alveolar minute ventilation and recruiting collapsed alveoli.
Application
Better chance of survival: A meta-analysis suggested that NIV improved survival in acute care settings – and that it is more beneficial when applied earlier rather than as a rescue therapy.
Fewer complications: NIV reduces the number of possible complications by 62% and treatment errors by 50%.
Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.
Reduced risk of infection: The use of NIV instead of mechanical ventilation is associated with a lower risk of nosocomial infections. A study has shown significantly more infectious complications related to the presence of the endotracheal tube.
Advantage
HFNC (High Flow) mode, 21~100% FiO2, 31~40℃, 10~70L/min air oxygen mixture of humidified gas.
6-level (100~600ms) pressure rise time, to meet the physiological needs of different flow rates at the beginning of inspiration.
The pressure is measured on mask side. The pressure measuring hose is connected to the near pressure measuring port on the left side of the machine and the tee at the lower end of the mask (inside the package of the mask) to collect the pressure in the mask.
Leakage compensation performance, the device offers 120 L/min maximum leakage compensation, it can also achieve a preset target pressure to form a pressure platform to complete accurate trigger and switch.
All equipment and consumables are developed and produced by Micomme with guaranteed performance, supply and after-sales service.